Have you been many years at your position but haven't got a promotion? Or are you a new comer in your company and eager to make yourself outstanding? Our NSE7_LED-7.0 exam materials can help you. With our NSE7_LED-7.0 exam questions, you can study the most latest and specialized knowledge to deal with the problems in you daily job as well as get the desired NSE7_LED-7.0 Certification. You can lead a totally different and more successfully life latter on.

We provide three versions to let the clients choose the most suitable equipment on their hands to learn the NSE7_LED-7.0 exam guide such as the smart phones, the laptops and the tablet computers. We provide the professional staff to reply your problems about our NSE7_LED-7.0 study materials online in the whole day and the timely and periodical update to the clients. So you will definitely feel it is your fortune to buy our NSE7_LED-7.0 Exam Guide question. If you want to pass the NSE7_LED-7.0 exam, you should buy our NSE7_LED-7.0 exam questions.

>> NSE7_LED-7.0 Pdf Braindumps <<

Fortinet NSE7_LED-7.0 Reliable Practice Questions & New NSE7_LED-7.0 Exam Cram

In a knowledge-based job market, learning is your quickest pathway, your best investment. Knowledge is wealth. Modern society needs solid foundation, broad knowledge, and comprehensive quality of compound talents. Our NSE7_LED-7.0 certification materials can help you transfer into a versatile talent. Many job seekers have successfully realized financial freedom with the assistance of our NSE7_LED-7.0 test training. All your dreams will be fully realized after you have obtained the NSE7_LED-7.0 certificate. Finding a good paying job is available for you. Good chances are few. Please follow your heart.

Becoming certified in the Fortinet NSE 7 - LAN Edge 7.0 Exam can help IT professionals advance their careers and demonstrate their expertise in managing and securing LAN edge networks. Fortinet NSE 7 - LAN Edge 7.0 certification can also help organizations ensure that their network security professionals have the knowledge and skills necessary to protect their networks from advanced threats.

Fortinet NSE7_LED-7.0 Certification is an excellent way for IT professionals to validate their skills in securing LAN edge environments. Fortinet NSE 7 - LAN Edge 7.0 certification provides candidates with a comprehensive understanding of Fortinet's LAN Edge solutions, which can help them to manage and secure their organization's network infrastructure more effectively. Additionally, the certification is recognized globally, making it an excellent choice for IT professionals who are looking to expand their career opportunities.

Fortinet NSE 7 - LAN Edge 7.0 Sample Questions (Q14-Q19):

NEW QUESTION # 14
Which CLI command should an administrator use to view the certificate verification process in real time?

  • A. diagnose debug application foauthd -1
  • B. diagnose debug application radiusd -1
  • C. diagnose debug application fnbamd -1
  • D. diagnose debug application authd -1

Answer: A

Explanation:
Explanation
According to the FortiOS CLI Reference Guide, "The diagnose debug application foauthd command enables debugging of certificate verification process in real time." Therefore, option A is true because it describes the CLI command that an administrator should use to view the certificate verification process in real time. Option B is false because diagnose debug application radiusd -1 enables debugging of RADIUS authentication process, not certificate verification process. Option C is false because diagnose debug application authd -1 enables debugging of authentication daemon process, not certificate verification process. Option D is false because diagnose debug application fnbamd -1 enables debugging of FSSO daemon process, not certificate verification process.


NEW QUESTION # 15
Refer to the exhibit.

Examine the FortiGate user group configuration and the Windows AD LDAP group membership information shown in the exhibit FortiGate is configured to authenticate SSL VPN users against Windows AD using LDAP The administrator configured the SSL VPN user group for SSL VPN users However the administrator noticed that both the student and j smith users can connect to SSL VPN Which change can the administrator make on FortiGate to restrict the SSL VPN service to the student user only?

  • A. In the SSL VPN user group configuration, change Name to cn=sslvpn, CN=users, DC=trainingAD, Detraining, DC-lab.
  • B. In the SSL VPN user group configuration set Group Name to ::;=Domain users.CN-Users
    /DC=trainingAD, DC-training, DC=lab.
  • C. In the SSL VPN user group configuration change Type to Fortinet Single Sign-On (FSSO)
  • D. In the SSL VPN user group configuration set Group Nam to CN-SSLVPN, CN="users, DC- trainingAD, DC-training, DC-lab

Answer: D

Explanation:
According to the FortiGate Administration Guide, "The Group Name is the name of the LDAP group that you want to use for authentication. The name must match exactly the name of the LDAP group on the LDAP server." Therefore, option A is true because it will set the Group Name to match the LDAP group that contains only the student user. Option B is false because changing the Name will not affect the authentication process, as it is only a local identifier for the user group on FortiGate. Option C is false because setting the Group Name to Domain Users will include all users in the domain, not just the student user. Option D is false because changing the Type to FSSO will require a different configuration method and will not solve the problem.


NEW QUESTION # 16
Which two statements about the guest portal on FortiAuthenticator are true? (Choose two.)

  • A. The guest portal provides pre and post-log in services
  • B. Administrators can use one or more incoming parameters to configure a mapping rule for the guest portal
  • C. Each remote user on FortiAuthenticator can sponsor up to 10 guest accounts
  • D. Administrators must approve all guest accounts before they can be used

Answer: A,B

Explanation:
The guest portal on FortiAuthenticator can offer services both before and after a guest logs in, such as displaying terms of use before login and providing access to network resources after successful authentication.
Administrators have the ability to configure mapping rules for the guest portal using various incoming parameters. This allows for flexible and dynamic handling of guest account creation and access permissions based on different criteria.


NEW QUESTION # 17
Refer to the exhibit.

Examine the debug output shown in the exhibit
Which two statements about the RADIUS debug output are true'' (Choose two)

  • A. The user student belongs to the SSLVPN group
  • B. User authentication succeeded using MSCHAP
  • C. User authentication failed
  • D. The RADIUS server sent a vendor-specific attribute in the RADIUS response

Answer: A,D


NEW QUESTION # 18
Refer to the exhibit.

Examine the FortiManager configuration and FortiGate CLI output shown in the exhibit An administrator is testing the NAC feature The test device is connected to a managed FortiSwitch device
{S224EPTF19"53€7)onport2
After applying the NAC policy on port2 and generating traffic on the test device the test device is not matching the NAC policy therefore the test device remains m the onboarding VLAN Based on the information shown in the exhibit which two scenarios are likely to cause this issue? (Choose two.)

  • A. Device detection is not enabled on VLAN 4089
  • B. The MAC address configured on the NAC policy is incorrect
  • C. Management communication between FortiGate and FortiSwitch is down
  • D. The device operating system detected by FortiGate is not Linux

Answer: A,D

Explanation:
According to the FortiManager configuration, the NAC policy is set to match devices with the MAC address of 00:0c:29:6a:2b:3c and the operating system of Linux. However, according to the FortiGate CLI output, the test device has a different MAC address of 00:0c:29:6a:2b:3d. Therefore, option B is true. Option A is also true because the FortiSwitch device status is shown as down, which means that the management communication betweenFortiGate and FortiSwitch is not working properly. This could prevent the NAC policy from being applied correctly. Option C is false because the device operating system detected by FortiGate is Linux, which matches the NAC policy. Option D is false because device detection is enabled on VLAN 4089, as shown by the command "config switch-controller vlan".


NEW QUESTION # 19
......

Passing the Fortinet NSE7_LED-7.0 is the primary concern. To pass the hard NSE7_LED-7.0 exam on the first try, you must invest more time, effort, and money. To pass the NSE7_LED-7.0 Exam, you must have the right Fortinet NSE 7 - LAN Edge 7.0 NSE7_LED-7.0 Exam Dumps, which are quite hard to get online. Get it right away to begin preparing. ActualVCE is a reputable platform that has been providing valid, real, updated, and error-free Fortinet NSE 7 - LAN Edge 7.0 NSE7_LED-7.0 Exam Questions.

NSE7_LED-7.0 Reliable Practice Questions: https://www.actualvce.com/Fortinet/NSE7_LED-7.0-valid-vce-dumps.html

BTW, DOWNLOAD part of ActualVCE NSE7_LED-7.0 dumps from Cloud Storage: https://drive.google.com/open?id=1R5FgCflhW8YtMX1S-PQnxsujfAlFPExz

Report this page